Characteristics of External Thread, Double Secure Cap
1. Excellent sealing performance: permanent reversal prevention;
2. High storage safety: the inside forms a closed and isolated space separated from the outside without leakage, favorable for storage and transportation.
3. Memory of use history: the middle cover will be punctured when taking sample out, that is, leave a used mark. This function is to ensure the original fidelity of the sample;
4. Convenient sampling without contamination: the soft rubber sealing layer can be punctured with a pipette tip or a syringe needle. The outer cover won’t be contaminated by the sample, ensuring safety of the personnel and environment.
3D Barcode Cryogenic Vial, SBS Format
The product meets the SBS standard and provides an effective safety guarantee and management for biological sample libraries and other warehouses of various chemicals and biological products stored at low temperatures.
| Cat. No. | Product Description | Pack |
| 627102 | 3D Barcode 1.8 mL Cryogenic Vial, Self-Standing, External Thread, Double Secure Cap | 10*10/Rack, 10 racks /Cs, 1000 vials/Cs |
| 627002 | 3D Barcode 1.8 mL Cryogenic Vial, Self-Standing, External Thread | 10*10/Rack, 10 racks /Cs, 1000 vials/Cs |
| 627101 | 3D Barcode 1.8 mL Cryogenic Vial, Self-Standing, | 50/Pk, 2000Cs |
| Bulk,External Thread, Double Secure Cap | ||
| 627001 | 3D Barcode 1.8 mL Cryogenic Vial, Self-Standing, Bulk,External Thread | 50/Pk, 2000Cs |
| 612041 | 3D Barcode 1.9 mL Cryogenic Vial, SBS Format, Self-Standing, External Thread, Caps on, Sterile | 48/Pk, 480/Cs |
| 612047 | 3D Barcode 1.9 mL Cryogenic Vial, SBS Format, Self-Standing, External Thread, Caps Separated, Sterile | 48 Vials/Pk, 48 Caps/Pk, 480/Cs |
| 614041 | 3D Barcode 4.0 mL Cryogenic Vial, SBS Format, Self-Standing, External Thread, Caps on, Sterile | 48/Pk, 480/Cs |
| 614047 | 3D Barcode 4.0 mL Cryogenic Vial, SBS Format, Self-Standing, External Thread, Caps Separated, Sterile | 48 Vials/Pk, 48 Caps/Pk, 480/Cs |
Precautions:
1. After the cryogenic vial is taken out of the liquid nitrogen, its bottom should be wiped with a dry towel, so that the QR code can be better identified;
2. The freezing storage sample size should not exceed the maximum working volume required by the cryogenic vial;
3. During the freezing storage, the vial cap must be tightened, to prevent liquid nitrogen from entering during the freezing process;
4. Before the cryogenic vial is taken out of the liquid nitrogen, proper protective measures should be taken first, to avoid causing safety problems in the laboratory.